P/No. EL6630
Specifications

Input Signal Device : Hall Effect sensor (pulser)
 Max. input frequency : 0 to 5,000 Hz
 Power Supply Range : Filtered DC power required,
8-28 VDC maximum
Customer supplied, 250 mA
 Idle Current Draw : 0.10 Amps @ 28 VDC
 Max. Current Draw,
Both Channels : 200 mA
 Output Signal : 100 mA per channel into
a 0.1
μf load, sink or source
750’ (230 m) 18-20 AWG wire
 Connections : 2.4 mm screwdriver terminals
(wire sizes 14-20 AWG)
 Temperature : -40ºF/+158ºF (-40ºC/+70ºC)
 Dimensions : 2.10” x 0.98” x 0.38”
52.5 x 24.9 x 9.5 mm
 Enclosure options : Local NEMA 3R
Local or remote NEMA 4X
Local or remote NEMA 7/4X
3 . 1
PIA-300 Pulse Isolator, Amplifier & Splitter (optional component)
The purpose of the PIA-300 is to provide:
 Protection and properly interface the signal from the Hall
Effect sensor (pulser) to customer supplied electronics
(totalizer, register, PLC, etc.).
 Supply SOURCE signal in place of standard sink.
 Amplification of output signal, so it can be transmitted
over greater distances.
 Two identical output signals, which can be sent to two
different destinations.
This component can be supplied either unmounted (as an
encapsulated circuit pack), or installed in a variety of option-
al enclosures. In some cases it can be mounted internally in
the remote receiving instrument.
1 ISP-3 INPUT (A)
2 COMMON
3 COMMON
4 LOGIC INPUT (B)
5 PULL UP
6 PROGRAM
7 PROGRAM
8 +8 TO 28VDC
9 +8 TO 28VDC
10 (A) OUT
11 COMMON
12 COMMON
13 (B) OUT
The PIA-300 is often used in conjunction with PC58 or
PCDT58 to provide a pulse signal. In those systems, the
PIA-300 can be wired in one of two positions:
A:
B:
A = High frequency, non-scaled pulse signal to the remote
instrument (raw meter signal).
B = Low frequency (max. 8 Hz), scaled pulse signal from
the register/totalizer to the remote instrument.
HE
PULSER
PIA
300
PC58
HE
PULSER
PC58
PIA
300