TS Series S & E●● assy. 316 Stainless Steel, Electronic Output Manual FPPMS12, Rev. 2008-03 Installation, Operation & Parts Manual Flow
Reduced Flow Rate Strainer basket partially blocked. Clean the basket. Pump not functioning correctly. Repair pump. Valve stuck in partially
Regular Maintenance (1-3 years) A. Pulser O-ring (15) Very Long Term Wearing Components (3-10 years) B. Transfer Gear/Disc Magnet repair kit (10 &
both gears with a soft pencil for easy alignment when re-installing the gears. 6. When re-installing the oval gears (2), place the upper gear so that
TS Series - Exploded View, Electronic 1 . 13 Torque & Tool ChartDESCRIPTIONTS10C TS15C TS20C TS30CDust cover screwTool1/4" nut driver 1/4&q
Parts Lists – TS10C, TS15C, TS20C & TS30C 1 . 14 Meter case depth:CapacityItem DESCRIPTION qtyPart No.qtyPart No.qtyPart No.qtyPart No.qtyPart No
Warranty 1 . 15 Tuthill Transfer Systems (“Manufacturer”) warrants to each buyer of its FPP Meters products (the “Buyer”) for a period of 12 months fr
INDEX Section . Page FPP Meters and Principle of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .
About FPP Meters We thank you for purchasing an FPP Meter for liquid meas-urement service. FPP Meters, formerly Fluid Power Prod-ucts, is now a trade
SAFETY INSTRUCTIONS Make sure that all necessary safety precautions have been taken, including proper clothing, personal safety equipment and fire saf
Reversing Direction of Flow When a flow meter has been ordered for Left-to-Right flow, but Right-to-Left is found to be more practical, the flow meter
TS Series - Pulse Pick-Ups 1 . 6 Hall Effect Sensor (standard pulser) FLAME PROOF RATED SENSORS EEx d FOR ZONE 1 APPLICATIONS. ExII 2 G CE0344 EEx
TS Series - Pulse Pick-Ups, continued 1 . 7 Hall Effect Sensor (standard pulser) TESTING FOR HALL EFFECT PULSER OPERATION There are three system co
These shifts in the accuracy curve illustrate the need for field recalibration of new flow meters after installation in place of service. Frequency o
Flow Meter Specifications Model Nominal Pressure Rating¹ at 100°F (38°C): Flow Meter ² 400 PSI 28 BAR 2750 kPa Strainer² 400 PSI 28 BAR